82 PbLead207.2

Lead

Element Density: 11.34 g/cm3
Electron Configuration:
[Xe]4f145d106s26p2
Oxidation States: +2,4
Major Edges
L313035
M42586
M52484
O422
O519
Minor Edges
L115861
L215200
M13851
M23554
M33066
N1894
N2764
N3645
N4435
N5413
N6143
N7138
O1147
O2105
O386

Considerations

The M4,5-edge that shows both a strong cross-section and typically low background due to its high energy. To efficiently measure this edge, a large collection angle must be used. Some TEMs do not support high energy loss at short camera lengths due to cut off apertures in the column. Sudden drops in the power law background at high energy typically indicate cut off in the column.

Pb electropolished foil_0-0180eV

  • Material Analyzed:
    Pb
  • Related Elements:Lead
  • Data Contributor:Gatan
  • Beam energy (keV):200
  • Nominal energy range (eV):0 - 180
  • Collection semi-angle effective (mrad):100
  • Notes:

    Serial EELS; slightly oxidized; 10 sweeps 16.67 ms dwell

Pb electropolished foil_0-3890eV

  • Material Analyzed:
    Pb
  • Related Elements:Lead
  • Data Contributor:Gatan
  • Beam energy (keV):200
  • Nominal energy range (eV):0 - 3890
  • Collection semi-angle effective (mrad):100
  • Notes:

    Serial EELS; slightly oxidized; zero-loss peak intensity = 5.17e9; total elastic int. / zero-loss int. = 0.21; gain change factor = 672; 70 sweeps 10 ms dwell; saturated zero-loss